Service note for JA-112E Wired control panel with RFID The access module is a component of the JABLOTRON JA-100 system. Thanks to the surface-mounted system, it is possible to put together a configuration tailored to the system size and user requirements. The product is intended to be installed by a trained...
Too much choice? Chat or call us at 085-0160316

  • Display
  • Display

Best selling Featured Best selling Alphabetical: A-Z Alphabetical: Z-A Price: low to high Price: high to low Date: old to new Date: new to old

There are no products in these categories. Shop on.

112e

Service note for JA-112E

Wired control panel with RFID

The access module is a component of the JABLOTRON JA-100 system. Thanks to the surface-mounted system, it is possible to put together a configuration tailored to the system size and user requirements. The product is intended to be installed by a trained technician with a valid Jablotron certificate.
The wired access module (4) contains the first control segment (1). This configuration can be extended by the desired number of JA-192E segments (up to max. 20 per configuration).



Figure: 1 - operating segment; 2 - segment keys; 3 - illuminated activation key; 4 - RFID module; 5 - terminals for opening module;



Figure: 6 - connector connection audio module; 7 - connector control segments; 8 - terminal for interconnection of audio module with the control unit; 9 - terminal bus; 10 - serial number; 11 - sabotage switch

Installation
1. Successively press the four clamps on sides (see fig. 1) and detach the module from the plastic back panel.
2. When installing a subsequent operating segment, first remove the top cover from the 1st segment.
3. Remove the transparent covers from segments (by pulling forcefully on both sides at segment keys).
4. Always connect the guide wire of the segment to the connector of the previous segment and snap them together (it is best to always rotate the guide wires, turning the segment by 360° - this way the wires do not accidentally get caught between the plastic parts). Install all desired control segments in the same way. Finally, replace (snap in) the sealing cap.
5. Pull the cable through the plastic back panel and screw down the back panel with segments at the selected position. If using several control segments, also secure the segments against the wall (choose the number of screws as required).
6. Connect bus cable to the connection terminal (9).

For connecting the BUS, the system must be disconnected from the power supply.

7. Connect supply for segments to the module's internal connector (7).
8. Snap RFID module into the configuration.
9. Continue to follow the instructions for installation of the central unit. Basic steps:
a. After switching on, the yellow signal light flashes because the module has not been read into the system.
b. In the F-Link programme, select the required position on the peripherals card and start the learning mode with the Read button.
c. Press the illuminated activation key (3), causing the module to learn and the yellow light will extinguish.
10. After assembly is complete, insert description labels into the segment covers and close the covers. Description labels are printed as part of the F-Link programme (Peripheral devices card, at the position of the RFID module - Internal setting).



Figure: placing description label in the operating segment.

Setting properties
This is done by the F-Link programme - Peripheral devices card. On the position of the RFID module use Internal setting. The present configuration appears, with possibility of setting its properties. Individual segments can be assigned the desired functions (operation sections, signalling state of sections, alarm striking, operation PG output, signalling state PG output, etc.). Details can be found in the F-Link programme.

Configuration change
If the configuration of segments is to be changed, pull them apart at the joint location, on the sides (on the side of the keys).




Technical parameters
Power supply from the central unit bus (9...15 V)
Current consumption at standby (idle) 10 mA
Current consumption for cable selection 15 mA
Each added operating segment 0.5mA
Operating frequency RFID 125 kHz
Range of operating temperatures -10 to +40 °C
Environments according to CSN EN 50131-1 II. indoors, general
Classification grade 2
compliant with CSN EN 50131-1, CSN EN 50131-3,
Further complies with CSN ETSI EN 300330, CSN EN 50130-4
CSN EN 55022, CSN EN 60950-1
Conditions for operation CTÚ no. VO-R/10/09.2010-11

Product JA-112E is designed and manufactured in accordance with the provisions to be applied to it: Government Decree No. 426/2000 Sb. in the text of subsequently promulgated regulations, if used according to its intended use.

Note: Although this product does not contain harmful materials, do not dispose of it in the domestic waste, but dispose of it at the collection point intended for electronic waste.

Login

Forgot your password?

Don't have an account yet?
Create a free account and enjoy many benefits.

SufioVAT.opKar();

Notify me!

We will send you an email when this article is back in stock

Notify me!

Thank you, you will be notified when this item is back in stock.