JA-81E (0)

Service instructions for JA-81E 1 Installation The installation of Oasis components is reserved only for and distributor-certified installers. The control panel is designed for indoor use, especially for the main entrance door of a property.1. Open the housing of the control panel. by pressing the TAB at the bottom using...
Too much choice? Chat or call us at 085-0160316

  • Display
  • Display

Best selling Featured Best selling Alphabetical: A-Z Alphabetical: Z-A Price: low to high Price: high to low Date: old to new Date: new to old

There are no products in these categories. Shop on.

jablotron-ja-81e-bedraad-codebedienpaneel

Service instructions for JA-81E

1 Installation

The installation of Oasis components is reserved only for and distributor-certified installers. The control panel is designed for indoor use, especially for the main entrance door of a property.
1. Open the housing of the control panel. by pressing the TAB at the bottom using a screwdriver
2. Install the base plate at the desired location.
3. Connect the cable to the control panel. There are two options:
- Use a flat telephone cable with RJ connectors (max. 10 metres). There is a digital bus in the control panel and the control panel. (This is only intended for a temporary installation)
- Use a braided cable 4 wire (max. 100mtr) - The corresponding marked contacts should be connected to each other. Via the cable wires (GND, A, B, +U)
4. Install the external door detector (if used ) and connect its wiring to the IN and GND terminals
5. Reconnect the control panel internal wiring back in place
6. Control panel programming instructions can be found in the installation manual of the control panel

.

2 Setting the display status enable/disable

According to the EN standard, the control panel will not display the status of the system being switched ON or OFF. The status can only be read during operation or an entrance delay. However, it is possible to still show this indication on the display, however, after consideration this will have to be set via programming.

3 Installation of a door detector

It is possible to connect a wired detector to the control panel via the IN input. The IN input contact will be triggered when the GND is disconnected. The natural reaction from the control panel to the IN input will give an activated delay intrusion alarm. ( non-changeable reaction)

Note:
- If the IN input is not used, connect it to the GND.
- The IN input only reports the disconnection of the magnetic contact to the control panel, (it does not indicate open door status).

4 Controlling the PgX output

The PgX output can be switched on and off by holding down the Ü (on) and the # (off) for 5 seconds. The function of the PgX must be set via the control panel. A long tone confirms the setting.

5 Entering control panel text

It is recommended to use a PC with OLink software to set the text. If you change the text in the system using OLink, the change will take place in all control panels. If you want to use a new control panel you can synchronise your modified texts with the new control panel.
The names can be entered via the control panel in the ''Edit Text'' menu - for this see the installation manual of the control panel. The entered text is only stored in the control panel used for data entry.

Login

Forgot your password?

Don't have an account yet?
Create a free account and enjoy many benefits.

SufioVAT.opKar();

Notify me!

We will send you an email when this article is back in stock

Notify me!

Thank you, you will be notified when this item is back in stock.